7.1 HIGH
- CVSS version (CVSS): 4.0
- Attack Vector (AV): Network (N)
- Attack Complexity (AC): Low (L)
- Attack Requirement (AT): None (N)
- Privileges Required (PR): Low (L)
- User Interaction (UI): None (N)
- Vulnerable System Impact Confidentiality (VC): None (N)
- Vulnerable System Impact Integrity (VI): None (N)
- Vulnerable System Impact Availability (VA): High (H)
- Subsequent System Impact Confidentiality (SC): None (N)
- Subsequent System Impact Integrity (SI): None (N)
- Subsequent System Impact Availability (SA): Low (L)
- Automatable (AU): Yes (Y)
- Recovery (R): Automatic (A)
- Vulnerability Response Effort (RE): Moderate (M)
- Modified Attack Vector (MAV): Network (N)
- Modified Attack Complexity (MAC): Low (L)
- Modified Attack Requirement (MAT): None (N)
- Modified Privileges Required (MPR): Low (L)
- Modified User Interaction (MUI): None (N)
- Modified Vulnerable System Impact Confidentiality (MVC): None (N)
- Modified Vulnerable System Impact Integrity (MVI): None (N)
- Modified Vulnerable System Impact Availability (MVA): High (H)
- Modified Subsequent System Impact Confidentiality (MSC): Negligible (N)
- Modified Subsequent System Impact Integrity (MSI): Negligible (N)
- Modified Subsequent System Impact Availability (MSA): Low (L)
- Safety (S): Not Defined (X)
- Value Density (V): Not Defined (X)
- Provider Urgency (U): Not Defined (X)
- Confidentiality Req. (CR): Not Defined (X)
- Integrity Req. (IR): Not Defined (X)
- Availability Req. (AR): Not Defined (X)
- Exploit Maturity (E): Not Defined (X)
Activity log
- Created & dismissed (no matching packages found) suggestion
Junos OS: EX Series: Subscribing to an unsupported telemetry sensor path causes fxpc process crash
An Improper Handling of Undefined Parameters vulnerability in the packet forwarding engine (pfe) of Juniper Networks Junos OS on EX Series devices allows an authenticated attacker with low privileges to cause a Denial-of-Service (DoS). If an attempt is made to subscribe to an unsupported telemetry sensor path on EX2300, EX3400, EX4000, EX4100 and EX4400 via gRPC, this causes the FPC to crash. This leads to a complete service outage until the module has automatically restarted. The following log message can be seen when this issue happens: agentd[<PID>]: AGENTD_RESOURCE_NOT_FOUND: No resource name found for <sensor> This issue affects Junos OS on EX2300, EX3400, EX4000, EX4100 and EX4400 devices: * all versions before 23.2R2-S7, * 23.4 versions before 23.4R2-S8, * 24.2 versions before 24.2R2-S5, * 24.4 versions before 24.4R2.
References
-
https://supportportal.juniper.net/JSA110092 vendor-advisory
Affected products
- <23.4R2-S8
- <24.2R2-S5
- <24.4R2
- <23.2R2-S7