5.3 MEDIUM
- CVSS version (CVSS): 4.0
- Attack Vector (AV): Network (N)
- Attack Complexity (AC): Low (L)
- Attack Requirement (AT): None (N)
- Privileges Required (PR): Low (L)
- User Interaction (UI): None (N)
- Vulnerable System Impact Confidentiality (VC): None (N)
- Vulnerable System Impact Integrity (VI): None (N)
- Vulnerable System Impact Availability (VA): Low (L)
- Subsequent System Impact Confidentiality (SC): None (N)
- Subsequent System Impact Integrity (SI): None (N)
- Subsequent System Impact Availability (SA): None (N)
- Automatable (AU): Yes (Y)
- Recovery (R): Automatic (A)
- Value Density (V): Concentrated (C)
- Vulnerability Response Effort (RE): Moderate (M)
- Provider Urgency (U): Green (Green)
- Modified Attack Vector (MAV): Network (N)
- Modified Attack Complexity (MAC): Low (L)
- Modified Attack Requirement (MAT): None (N)
- Modified Privileges Required (MPR): Low (L)
- Modified User Interaction (MUI): None (N)
- Modified Vulnerable System Impact Confidentiality (MVC): None (N)
- Modified Vulnerable System Impact Integrity (MVI): None (N)
- Modified Vulnerable System Impact Availability (MVA): Low (L)
- Modified Subsequent System Impact Confidentiality (MSC): Negligible (N)
- Modified Subsequent System Impact Integrity (MSI): Negligible (N)
- Modified Subsequent System Impact Availability (MSA): Negligible (N)
- Safety (S): Not Defined (X)
- Confidentiality Req. (CR): Not Defined (X)
- Integrity Req. (IR): Not Defined (X)
- Availability Req. (AR): Not Defined (X)
- Exploit Maturity (E): Not Defined (X)
Activity log
- Created & dismissed (no matching packages found) suggestion
Junos OS and Junos OS Evolved: Receipt of a specific SNMPv3 request results in memory leak and eventual snmpd crash
An Out-of-bounds Write vulnerability in the SNMP daemon (snmpd) of Juniper Networks Junos OS and Junos OS Evolved allows an authenticated network-based attacker sending specific valid SNMPv3 queries to trigger a memory leak. Over time, continuous receipt of these queries will result in snmpd process memory exhaustion, resulting in a process crash and restart, impacting the ability to monitor the system via SNMP. Memory usage can be monitored using the following command: user@device> show system processes extensive | match snmpd This issue affects: Junos OS: * all versions before 21.2R3-S8; * from 21.4 before 21.4R3-S7; * from 22.1 before 22.1R3-S6; * from 22.2 before 22.2R3-S4; * from 22.3 before 22.3R3-S3; * from 22.4 before 22.4R3-S2; * from 23.2 before 23.2R2; * from 23.4 before 23.4R2. Junos OS Evolved: * all versions before 21.2R3-S8-EVO; * from 21.4 before 21.4R3-S7-EVO; * all versions of 22.1-EVO, * from 22.2 before 22.2R3-S4-EVO; * from 22.3 before 22.3R3-S3-EVO; * all versions of 22.4-EVO, * from 23.2 before 23.2R2-EVO; * from 23.4 before 23.4R2-EVO.
References
-
https://supportportal.juniper.net/JSA110074 vendor-advisory
Affected products
- <22.1R3-S6
- <22.4R3-S2
- <21.2R3-S8
- <21.4R3-S7
- <23.2R2
- <22.3R3-S3
- <22.2R3-S4
- <23.4R2
- <22.2R3-S4-EVO
- <22.3R3-S3-EVO
- <21.2R3-S8-EVO
- <22.1*
- <21.4R3-S7-EVO
- <23.2R2-EVO
- <22.4*